Publication: Real-Time Monitoring of Breath Biomarkers with A Magnetoelastic Contactless Gas Sensor: A Proof of Concept
| dc.contributor.affiliation | "Instituto de Magnetismo Aplicado (IMA), Universidad Complutense de Madrid-Administrador de Infraestructuras Ferroviarias (UCM-ADIF), Las Rozas, 28230, Spain"," Departamento de Física de Materiales, Universidad Complutense de Madrid (UCM), Madrid, 28040, Spain"," Grupo de Tecnología de Sensores Avanzados (SENSAVAN), Instituto de Tecnologías Físicas y de la Información (ITEFI), Consejo Superior de Investigaciones Científicas (CSIC), Madrid, 28006, Spain"," Donostia International Physics Center, Donostia, 20018, Spain"," Instituto Madrileño de Estudios Avanzados (IMDEA) Nanociencia, Madrid, 28049, Spain"," Departamento de Ingeniería, Universidad de Nebrija, Madrid, 28015, Spain" | en |
| dc.contributor.affiliation | 000000041762408X | |
| dc.contributor.author | Peña A. | |
| dc.contributor.author | Aguilera J.D. | |
| dc.contributor.author | Matatagui D. | |
| dc.contributor.author | de la Presa P. | |
| dc.contributor.author | Horrillo C. | |
| dc.contributor.author | Hernando A. | |
| dc.contributor.author | Marín P. | |
| dc.date.accessioned | 2022-11-03T11:46:38Z | |
| dc.date.available | 2022-11-03T11:46:38Z | |
| dc.date.issued | 2022 | |
| dc.format.mimetype | application/pdf | |
| dc.identifier.doi | 10.3390/bios12100871 | |
| dc.identifier.uri | http://hdl.handle.net/20.500.12614/3192 | |
| dc.issue.number | 871 | |
| dc.journal.title | Biosensors | |
| dc.language.iso | en | |
| dc.relation.projectIDTEMP | Author A.P. received funding from grant PRE2019-0875001234, Ministerio de Ciencia e Innovación (MCI), Spain. D.M. received funding from Comfuturo, Consejo Superior de Investigaciones Científicas, Spain. Authors A.P., D.M., P.M. and C.H. received funding from projects RTI2018-095856-B-C21 and RTI2018-095856-B-C22, Ministerio de Ciencia e Innovación, Spain. A.P. and P.M. received funding S2018/NMT-4321, Comunidad de Madrid. J.D.A received funding from Next Generation EU, Ministerio de Trabajo y Economía, Comunidad de Madrid, Spain, Programa Investigo from grant 96-UCM-INV. | |
| dc.rights | Atribución-NoComercial-SinDerivadas 3.0 España | * |
| dc.rights | Atribución-NoComercial-SinDerivadas 3.0 España | * |
| dc.rights.accessRights | open access | |
| dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ | * |
| dc.title | Real-Time Monitoring of Breath Biomarkers with A Magnetoelastic Contactless Gas Sensor: A Proof of Concept | |
| dc.type | research article | |
| dc.type.hasVersion | VoR | |
| dc.volume.number | 12 | |
| dspace.entity.type | Publication |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- RealTime-Monitoring-of-Breath-Biomarkers-with-A-Magnetoelastic-Contactless-Gas-Sensor.pdf
- Size:
- 6.61 MB
- Format: