Publication: Cryo-soft X-ray tomography as a quantitative three-dimensional tool to model nanoparticle: Cell interaction
dc.contributor.affiliation | "Centro Nacional de Biotecnolog?a (CNB-CSIC), Cantoblanco, Madrid, 28049, Spain"," National Heart and Lung Institute, Imperial College London, Exhibition Road, London, SW7 2AZ, United Kingdom"," MISTRAL Beamline-Experiments Division, ALBA Synchrotron Light Source, Cerdanyola del Vall?s, Barcelona, 08290, Spain"," Laboratory for Synchrotron Radiation-Catalysis and Sustainable Chemistry, Paul Scherrer Institut (PSI), Villigen, 5232, Switzerland"," Institute for Soft Matter and Functional Materials, Microscopy Group Electron Storage Ring BESSY II, Helmholtz-Zentrum Berlin, Albert-Einstein-Str 15, Berlin, 12489, Germany"," Unidad Asociada CNB-Instituto Madrileno de Estudios Avanzados en Nanociencia (IMDEA Nanociencia), Cantoblanco, Madrid, 28049, Spain" | en |
dc.contributor.affiliation | 000000041762408X | |
dc.contributor.author | Chiappi M. | |
dc.contributor.author | Conesa J.J. | |
dc.contributor.author | Pereiro E. | |
dc.contributor.author | Sorzano C.O.S. | |
dc.contributor.author | RodrÃguez M.J. | |
dc.contributor.author | Henzler K. | |
dc.contributor.author | Schneider G. | |
dc.contributor.author | Chichón F.J. | |
dc.contributor.author | Carrascosa J.L. | |
dc.date.accessioned | 2020-12-15T12:40:34Z | |
dc.date.available | 2020-12-15T12:40:34Z | |
dc.date.issued | 2016 | |
dc.format.mimetype | application/pdf | en |
dc.identifier.doi | 10.1186/s12951-016-0170-4 | en |
dc.identifier.uri | http://hdl.handle.net/20.500.12614/2430 | |
dc.issue.number | 15 | en |
dc.journal.title | Journal of Nanobiotechnology | en |
dc.language.iso | en | en |
dc.relation.projectID | info:eu-repo/grantAgreement/EC/FP7/283570/EU/Transnational access and enhancement of integrated Biological Structure determination at synchrotron X-ray radiation facilities/BIOSTRUCT-X | en |
dc.relation.projectID | info:eu-repo/grantAgreement/EC/FP7/262943/EU/Multifunctional Nanotechnology for selective detection and Treatment of cance/MULTIFUN | en |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 España | * |
dc.rights | Atribución-NoComercial-SinDerivadas 3.0 España | * |
dc.rights.accessRights | open access | en |
dc.rights.uri | http://creativecommons.org/licenses/by-nc-nd/3.0/es/ | * |
dc.title | Cryo-soft X-ray tomography as a quantitative three-dimensional tool to model nanoparticle: Cell interaction | en |
dc.type | research article | en |
dc.type.hasVersion | VoR | en |
dc.volume.number | 14 | en |
dspace.entity.type | Publication |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Cryosoft-Xray-tomography-as-a-quantitative-threedimensional-tool-to-model-nanoparticle-Cell-interactionJournal-of-Nanobiotechnology.pdf
- Size:
- 2.22 MB
- Format:
- Adobe Portable Document Format